AM2320

From ElectroDragon Wiki
Revision as of 22:20, 21 December 2016 by Chao (talk | contribs) (→‎Documents)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
  • Dimension
Am2320.jpg

More Features

  • Long-term stability, relative humidity and temperature measurement, long signal transmission distance, digital signal output, accurate calibration, low power consumption, standard single bus digital interface, standard I 2 C bus digital interface, communication Way can be free to choose.

Humidity Features:

  • Resolution 0.1% RH
  • The range is 0-99.9% RH
  • Accuracy @ 25 ℃ ± 3% RH
  • Repeatability ± 0.1% RH
  • Interchangeability completely interchangeable
  • Response time 2 1 / e (63%) <5 s
  • Hysteresis ± 0.3% RH
  • Drift 3 Typical <0.5% RH / yr

Temperature:

  • Resolution 0.1 ° C or 16 bit
  • Accuracy ± 0.5 ℃
  • Measuring range -40 80 ℃
  • Repeatability ± 0.2 ℃
  • Interchangeability completely interchangeable
  • Response time 1 / e (63%) <5 s
  • Drift of ± 0.1 ℃ / yr

Electric Features:

  • Supply voltage 3.1 5 5.5 V
  • Power consumption 4
  • Sleep 8 10 μA
  • Measure 950 μA
  • Averaging 350 μA
  • Low-level output voltage Iol ^ 5 0-300 mV
  • High level output voltage Rp <25 kΩ 90% - 100% VDD
  • Low-level input voltage decreases by 0 - 30% of VDD
  • High level input voltage rises by 70% - 100% VDD
  • Rpu ^ 6 VDD = 5V / VIN = VSS 30 45 60 kΩ
  • Output current
  • Open 8 mA
  • Tri-state (off) 10 20 μA
  • Sampling period 2.0 S

Interface read data AM2320 serial interface, the sensor signal to read and power loss, have done the optimization. Sensor using a single bus, I2C two kinds of communication output, communication can be free to switch, easy to use. The bus interface determined by the level of SCL line when is powered up

  • SCL remains low for single bus communication mode on power-up;
  • SCL remains high at power-up and I2C communication mode.
  • Single bus is fully compatible with other products of the company's single-bus communication;
  • I 2 C communication protocol in accordance with the I 2 C standard addressing, can be directly linked to the I 2 C bus (bus only allows hanging a product), no additional wiring, easy to use.

Read AM2320 sensor, in strict accordance with the two communication protocols and timing. Detailed communication protocol specific to see a single bus and I 2 C communication protocol detailed page.

Documents