TB6600
Use Guide TB6600, 6560
Note:
- Double check the wiring before to use, otherwise the module could be burnt.
- Do not use more than 3A motor
Wiring
Pin Definition
Name | Name2 | Description | Mode |
---|---|---|---|
+24V, GND | Motor power | ||
A+/-, B+/- | Motor phase A/B | ||
CLK +/- | PUL +/- | Pulse | |
CW +/- | DIR +/- | Direction | Clockwise on H-TTL, vice serse |
EN+ EN- | ENA, ENB | Enable | Standby/lock mode on H-TTL, vice serse |
- CLK, CW and EN can be configured to work as high TTL or Low TTL
- Default TTL signal is 5V, If use 12V signal, serial connect a 1K resistor, if use 24V signal, serial connect a 2.4K resistor
Configuration TB6560
Dimension
Quick Start and Troubleshoot
- Use accelStepper library, modified demo code please check git-hub page here.
- No need to connect EN at beginning
- When alarm light up, double check voltage too small or big, double check motor wiring. Normally 16 division micro-setp can work well.
- Check demo video, if all wiring correct, double check or try division of micro-step.